Septic Tank Size per SNI 2398:2017: Dimensions by Users, Distances and Pipes

Septic tank size per SNI 2398:2017 depends on the number of users and the desludging interval. For a mixed system (toilet plus greywater) with 3-year desludging, Table 2 of the standard gives 5 users = 1.6 x 0.8 x 1.6 m (2.1 m3) and 10 users = 2.1 x 1.0 x 1.8 m (3.9 m3). This article summarises the size table, the septic tank distance from a well, pipe diameters and infiltration from the standard text we read on 23 October 2026, plus a homeX calculation.
Septic tank size per SNI 2398:2017 by users: table, distances and pipes
| Item | Value in the standard | Detail | homeX note | Source |
|---|---|---|---|---|
| Mixed system, 5 users | 1.6 x 0.8 x 1.6 m; total 2.1 m3 | Table 2, 3-year desludging | homeX check: 1.6 x 0.8 x 1.6 = 2.05 m3, matching the table | SNI 2398:2017 (BSN, salinan PDF) |
| Mixed system, 10 users | 2.1 x 1.0 x 1.8 m; total 3.9 m3 | Table 2 | homeX check: 3.78 m3 from the dimensions; the table rounds to 3.9 | SNI 2398:2017 (BSN, salinan PDF) |
| Mixed system, 15 / 20 / 25 users | 2.5 x 1.3 x 1.8 (5.8 m3); 2.8 x 1.4 x 2.0 (7.8 m3); 3.2 x 1.5 x 2.0 (9.6 m3) | Table 2; 50 users = 4.4 x 2.2 x 2.0 m (19.4 m3) | Suits boarding houses, small offices or shophouses | SNI 2398:2017 (BSN, salinan PDF) |
| Separate system (toilet only) | 10 users 1.6 x 0.8 x 1.3 m (1.66 m3); 25 users 2.4 x 1.2 x 1.6 m (4.6 m3) | Table 2; the table has no 5-user entry for the separate system | Kitchen and bathing water is treated separately | SNI 2398:2017 (BSN, salinan PDF) |
| Shape and minimum dimensions | Rectangular, length:width 2:1 to 3:1; min width 0.75 m; min length 1.50 m; min height 1.5 m including 0.3 m freeboard | Clause 4.2.1.2 a) | Inspection hole at least 0.40 x 0.40 m, rim 10 cm above ground | SNI 2398:2017 (BSN, salinan PDF) |
| Distance of infiltration from buildings, wells and rain wells | Building 1.5 m; drinking-water well 10 m; rain infiltration well 5 m (well/field); up flow filter and sanitary garden 1.5 m to all three | Table 1, unless special treatment applies | Consistent with SNI 8456:2017 (5 m from a rain infiltration well) | SNI 2398:2017 (BSN, salinan PDF) |
| Waste pipe, slope and clean-out | PVC min 110 mm (4 in); min slope 2%; clean-out at bends over 45 degrees and 22.5 degree changes; a 90 degree bend = two 45 degree bends or an inspection chamber | Clause 4.2.1.2 b) | See PVC class D and AW pipes in the related homeX article | SNI 2398:2017 (BSN, salinan PDF) |
| Inlet, outlet and vent pipe | Outlet 63–110 mm lower than the inlet; T-junction submerged 200–315 mm; vent pipe 63 mm, at least 250 mm above ground | Clause 4.2.1.2 c) and d) | Vent end faces down with a mesh screen | SNI 2398:2017 (BSN, salinan PDF) |
| Infiltration well (max 10 users) | Diameter 800 mm, depth 1.00 m, filled with 30–80 mm gravel or crushed stone | Clause 4.2.2.1 | Only for small tanks and a low water table | SNI 2398:2017 (BSN, salinan PDF) |
| Infiltration field (two lines) | I = 600 L/m2/day (0.10 m/h drop): 5 users 1.0 m; 10 users 2.0 m; 25 users 5.0 m; I = 120: 5 users 5.0 m, 25 users 25 m | Table 4 and Table 7; trench width min 500 mm, effective depth min 450 mm | Infiltration pipe over 15 m needs 2 lines, axis spacing at least 1.5 m | SNI 2398:2017 (BSN, salinan PDF) |
Source: the text of SNI 2398:2017 (PDF copy on the Yogyakarta city government site) read directly on 23 October 2026, covering Tables 1, 2, 4 and 7 and clause 4.2. The standard applies to up to 50 users. Data gaps: the tables give no prices, excavation costs or brands; local soil absorption and water-table checks are still needed; local regulations may differ; factory-made (bio) septic tanks have their own specifications.
Septic tank size for a 5-person house: homeX calculation
homeX analysis, not standard data. A 5-person family house uses a mixed system: internal size 1.6 x 0.8 x 1.6 m. Add wall thickness of about 12–15 cm (brick) and the cover slab, so the excavation is roughly 2.0 x 1.2 x 2.0 m. With absorption of 600 L/m2/day, a two-line field needs only 1.0 m per Table 4, but soil with low absorption (120) needs 5.0 m. Your own soil value must be tested, not assumed.
Concrete, brick or factory-made (bio) septic tank?
Table 3 of the standard allows plastered river stone, red brick or concrete block, unreinforced concrete, FRP and reinforced concrete for the tank body; all must be watertight. Factory bio septic tanks have their own sizes and claims; compare prices in the homeX article on bio septic tanks and do not equate them with the table figures above.
Buyer tips
- Count users (including guests and boarders) before choosing the size.
- Keep at least 10 m from a drinking-water well and 1.5 m from the building.
- Lay 110 mm pipe at a minimum 2% slope with clean-outs at every bend.
- Ask for a soil percolation test and measure the water table before digging the infiltration.
Request a septic tank size per SNI 2398 quote for your project
homeX can compare several brands at once and prepare a written quote for projects, renovations or shop stock. Send your needs (brand, size, quantity, location) via WhatsApp +62 821 1818 998, or visit the homeX showroom: Priskilla Tower, 6th floor, Jl. Atang Sanjaya No.21, Benda, Kota Tangerang, Banten 15125. Visit the homeX Showroom.
Disclaimer: prices change without notice and differ by store, city, pack size, grade and promotion. Data as of 23 October 2026; always confirm with the seller before buying.
FAQ
What size septic tank for 5 users per SNI? Mixed system with 3-year desludging: 1.6 x 0.8 x 1.6 m (total volume 2.1 m3) per Table 2 of SNI 2398:2017.
How far should a septic tank be from a well? Table 1 of the standard: effluent infiltration at least 10 m from a drinking-water well, 5 m from a rain infiltration well and 1.5 m from buildings; local soil conditions may demand more.
How often should a septic tank be desludged? The size table in SNI 2398:2017 is based on a 3-year desludging period; the design criteria cite a 2–5 year range.
Septic tank size per SNI 2398: related articles and products
Related articles:
- Bio Septic Tank Prices 2026: Pennyu PB6/PB12 & Penguin 1000 L
- PVC Pipe for Homes: AW vs D Class, SNI 06-0084-2002, Jointing and Pressure Testing
- PVC Pipe Price Indonesia 2026: Rucika AW, D & JIS per Length
- Clean Water Pipe Installation Cost 2026: per Point and per Metre
- Well Drilling Cost per Metre 2026: 20-60 m Packages and Pump Installation
Related products at homeX:
Price sources (checked 23 October 2026): SNI 2398:2017 (BSN, salinan PDF) — Procedure for septic tank design with advanced treatment (PDF).